Sanctuary at Centerpointe

Project Information Location – Altamonte Springs, Florida General Contractor – Jack Jennings & Sons Architect – Charlan Brock Architects Landscape Architect – Dix Hite Partners Website – sanctuarycenterpointe.com Scopes Barfield Fabricated and Installed Glass Balcony Railings Custom Art Panels on Garage Canopies Pool Fence & Gates Garage Entry Gates Ramp Handrails

Lake House By Alta

Location – Orlando, Florida General Contractor – Wood Partners Architect – Charlon Brock Architects Landscape Architect – Land Design Resource Group Website – lakehousebyalta.com Scopes Barfield Fabricated and Installed Balcony Railings 8 Foot Glass Wall Custom Pool Cabanas Custom Trellis Entry Canopy

Lake House Luxury Apartments

Location – Orlando, Florida General Contractor – Finfrock Architect – Finfrock Design, Inc Landscape Architect – Dix Hite + Partners Website – lakehouseapartmentsorlando.com

Residential Swimming Pool Barrier Requirements – Florida Building Code 6th Edition (2017)

454.2.17 Residential swimming barrier requirement. Residential swimming pools shall comply with Sections 454.2.17.1 through 454.2.17.3. Exception: A swimming pool with an approved safety pool cover complying with ASTM F1346. 454.2.17.1 Outdoor swimming pools. Outdoor swimming pools shall be provided with a barrier complying with Sections 454.2.17.1.1 through 454.2.17.1.14. 454.2.17.1.1 The top of the … Continue readingResidential Swimming Pool Barrier Requirements – Florida Building Code 6th Edition (2017)

Lakewalk at Hamlin

Location– Orlando, Florida General Contractor – Mark Baron Construction Architect – Charlan Brock & Associates Landscape Architect – Dix.Hite + Partners Website – lakewalkathamlin.com/

SWIMMING POOLS AND BATHING PLACES – FLORIDA BUILDING CODE 6TH EDITION (2017)

(Located in Florida Building Code Chapter 4 – Special Detailed Requirements based on Use and Occupancy) 454.1.3.1.9 All public pools shall be surrounded by a minimum 48 inch (1219 mm) high fence or other approved substantial barrier. The fence shall be continuous around the perimeter of the pool … Continue readingSWIMMING POOLS AND BATHING PLACES – FLORIDA BUILDING CODE 6TH EDITION (2017)

HANDRAILS – FLORIDA BUILDING CODE 6TH EDITION (2017)

(Located in Florida Building Code Chapter 10 – Means of Egress) 1014.1 Where required. Handrails serving stairways, ramps, stepped aisles and ramped aisles shall be adequate in strength and attachment in accordance with Section 1607.8. Handrails required for stairways by Section 1011.11 shall comply with Sections 1014.2 through 1014.9. Handrails required for ramps by Section 1012.8 shall comply with Sections 1014.2 through 1014.8. Handrails for stepped aisles and ramped aisles required by Section 1029.15 shall comply with Sections 1014.2 through 1014.8. 1014.2 Height. Handrail height, … Continue readingHANDRAILS – FLORIDA BUILDING CODE 6TH EDITION (2017)

Posted on 7 Comments

LOADS ON HANDRAILS AND GUARDS – FLORIDA BUILDING CODE 6TH EDITION (2017)

(Located in Florida Building Code Chapter 16 – Structural Design) 1607.8 Loads on handrails, guards, grab bars, seats and vehicle barriers. Handrails, guards, grab bars, accessible seats, accessible benches and vehicle barriers shall be designed and constructed for the structural loading conditions set forth in this section. … Continue readingLOADS ON HANDRAILS AND GUARDS – FLORIDA BUILDING CODE 6TH EDITION (2017)

Posted on 2 Comments

GUARDRAILS – FLORIDA BUILDING CODE 6TH EDITION (2017)

Florida Building Code SECTION 1015 GUARDS (Located in Florida Building Code Chapter 10 – Means of Egress) 1015.1 General. Guards shall comply with the provisions of Sections 1015.2 through 1015.7. Operable windows with sills located more than 72 inches (1829 mm) above finished grade or other surface below shall comply … Continue readingGUARDRAILS – FLORIDA BUILDING CODE 6TH EDITION (2017)

Posted on 9 Comments